Reference Documentation
For guidance on wiring a three-port valve and DHW cylinder temperature sensor, refer to:
📄 Grant Aerona³ (R32) Installation and Servicing Instructions (DOC 0136 Rev2.4, Feb. 2024)
Key Sections:
-
Appendix C (Page 81): Wiring for a three-port valve with hydraulic separation
-
Appendix M (Page 89): Wiring for a three-port valve with no hydraulic separation
Key Components for Installation
For a Grant Aerona³ installation with Homely, the most important components are:
✅ V4044C Diverter Valve
✅ Aerona³ Controller
✅ DHW Cylinder Temperature Sensor
✅ ASHP Terminals
Components that can left unconnected when using Homely
The following components should not be connected, as they are unnecessary:
🚫 HPIDTM4 DHW Timer
🚫 EP002 Heat Pump Interface
🚫 Hot Water Priority Relay (HPWPR1)
Additional Wiring Considerations
-
If zone valves, buffer valves, or secondary pumps are present, their contacts can be wired in as described in the Homely Installation Manual.
-
Since Homely sends heating/DHW commands directly to the Grant controller, no remote contacts need to be wired in.